Electric line towers
Polyhedral towers
Towers for ВЛ10кВ
СМ10АО
СМ10АП
СМ10АУ
СМ10П
Towers for ВЛ35кВ
АМ35-2Ф
ПМ35-2Ф
Towers for ВЛ110кВ
АМ110-3Ф4
ПС-110 кВ
ПМ110-2Ф
ПМ110-1Ф
ПМ110-4Ф
ПМ110-6Ф
ПМ110-1ФТ
Towers for ВЛ220кВ
АМ220-1
УМ220-1
КМ220-1
ПМ220-2Ф4
ПМ220-8Ф
ПМ220-7Ф
ПБМ220-2
ПБМ220-1
ПМ220-5
ПМ220-3
ПМ220-2Т.ТП
ПМ220-2Т
ПМ220-2Ф
ПМ220-1
Towers for ВЛ330кВ
МПГ330-1
МПГ330-1Т
Towers for ВЛ500кВ
ПМГ500-1
Lattice towers
Towers for ВЛ35кВ
У 35-1
У 35-2
ПБ 35-2
П 35-2В
Towers for ВЛ110кВ
У 110-1
У 110-2
У 110-3
У 110-4
П 110-2
П 110-3В
П 110-4В
П 110-5В
П 110-6В
ПБ 110-3
ПУС 110-2
ПС 110-9В
ПС 110-10В
УС 110-3
УС 110-8
4У 110
4П 110
Towers for ВЛ220кВ
У 220-1
У 220-2
У 220-3
П220-3
ПС 220-5
ПС 220-6
П 220-2Т
ПС 220-6Т
ПБ 220-1
Towers for ВЛ330кВ
УП 330-3
ПБ 330-7
У 330-2
П 330-2Т
П 330-3Т
ПС 330-5ПТ
Towers for Вл400кВ
П 400-2Т
У 400-2Т
Towers for ВЛ500кВ
ПБ1Т
ПБ2Т
ПБ4Т
ПБ4С
Р2
У2
У2СУ2
Towers for ВЛ750кВ
УС730-3
ПП 750-1
Multi-faceted towers and masts
Lighting poles, brackets
Round conical supports, nonpower
Multi-faceted conical supports, nonpower
Multi-faceted power (lines of force) supports
Multi-faceted power for catenary
Brackets
Lighting masts
High-mast supports with a mobile (lowerable) corona
Floodlight masts
Floodlight masts for lighting equipment in the reflected light
Folding lighting supports
Lightning divertors
Radio masts
Foundations
BARRIER FENCES
One-side barrier fencing of the road
11ДО/У1(130)-0,75-3,0-1,0
11ДО/У1(130)-0,75-4,0-1,5
11ДО/У2(190)-0,75-2,0-1,0
11ДО/У2(190)-0,75-3,0-1,5
11ДО/У3(250)-0,75-2,0-1,1
11ДО/У4(300)-0,75-1,5-0,88
11ДО/У3(250)-0,75-2,0-1,5
11ДО/У4(300)-0,9-2,0-1,05
11ДО/У5(350)-1,1-1,5-0,8
11ДО/У5(350)-1,1-1,5-0,85
11ДО/У5(350)-1,1-2,0-1,0
11ДО/У5(350)-1,1-2,25-1,1
11ДО/У6(400)-1,1-1,0-0,65
11ДО/У6(400)-1,1-1,5-0,91
11ДО/У6(400)-1,1-1,5-0,97
11ДО/У6(400)-1,1-2,0-1,13
11ДО/У6(400)-1,1-2,0-1,25
11ДО/У6(400)-1,1-2,25-1,24
11ДО/У7(450)-1,1-1,0-0,8
11ДО/У7(450)-1,1-1,5-1,02
11ДО/У7(450)-1,1-2,0-1,22
Double-sided barrier fencing of the road
11ДД/У4(300)-0,75-2,0-1,14
11ДД/У5(350)-1,1-2,5-79
11ДД/У5(350)-1,1-3,0-1,0
11ДД/У6(400)-1,1-2,0-0,74
11ДД/У6(400)-1,1-3,0-1,14
11ДД/У7(450)-1,1-1,5-0,66
11ДД/У7(450)-1,1-3,0-1,29
One-side barrier fencing of the pavement
11МО/У1(130)-0,75-2,0-0,75
11МО/У2(190)-0,75-1,5-0,75
11МО/У3(250)-0,75-2,25-0,68
11МО/У3(250)-0,9-2,25-0,70
11МО/У3(250)-1,1-2,25-0,9
11МО/У4(300)-0,75-2,0-0,68
11МО/У4(300)-0,9-2,0-0,70
Double-sided barrier fencing of the pavement
11МД/У4(300)-0,75-2,0-0,7
11МД/У5(350)-1,1-3,0-0,97
11МД/У5(350)-1,1-3,0-0,74
11МД/У6(400)-1,1-2,5-0,74
11МД/У8(500)-1,5-2,0-1,05
11МД/У10(600)-1,5-1,5-1,0
11МД/У10(600)-1,5-1,5-1,0
Railing fences
Трубчатое перильное ограждение
Секционное перильное ограждение
Accessory
Video
CULVERTS
Кульверты с гофром 150 х 50 мм
Circular culverts
Arched culverts
Vertical type ellipse culverts
Reduced type arched culverts
Raised type arched culverts
Polycentric culverts
Reduced type polycentric culverts
Horizontal type ellipse culverts
Culverts with a wavelength different from 152,4 mm
Prefabricated metal corrugated pipes
Section and physical characteristics for profile
Example of culvert’s assembly
Examples of culverts’ use
Кульверты с гофром 100 х 20 мм
Hot-dip galvanizing
General information
Corrosion
The corrosion process
Protection
Comparison of protection systems
Hot-dip galvanizing
Behavior of steel during a hot-dip galvanizing
Resistance of protection created by hot-dip galvanizing
advantage of hot-dip galvanizing
Other protection system with a zinc
Before hop-dip galvanizing

МК | Multi-faceted conical supports for street lighting

They designed for functional and decorative lighting of street, roads with a low or medium traffic volume, lighting, courtyards, embankments, avenues, boulevards, parks, public gardens, cottage settlements, gas stations, schools and childcare facilities and so on.

Console lighting, standard lamp, hanging lamps are installed on supports and towers. The supports are made of sheet metal with a thickness of 4 mm and have a octahedron in a cross-section.

The support material is selected on the basis of climatic zones (-50 to +50) and the operating conditions of support according to СНиП (building code) II-23-81, "Steel Structures".
Supply of power cable is in the ground (internal connection) with the service through the side hatch at the bottom of the support.

Installation methods:
МК-хФ- flange support mounted on a standard metal foundation (ФМ). Connection of support and ФМ is using by flange bolts or studs.
МК-хГ- straight support is installed in a prepared (drilled) hole and then underpour.
Coverage – hot-dip galvanizing ГОСТ 9.307-89


 

Installation MK support in the ground



Installation of MK support at the metal foundation

 

Name of supportНhdDSParameters of the flangewvWeight
АВD отв
mmmmmmmmmmmmmmmmmmmkg
Non-forcible multi-faceted conical flange supports  (installation on the flange)
МК-3Ф-603-60894190130204007026
МК-4Ф-604-60984190130204008035
МК-5Ф-605-601074190130204008045
МК-6Ф-756-751324220150244009067
МК-7Ф-757-751424220150244009081
МК-8Ф-758-75150425018024500100100
МК-9Ф-759-75159425018024500100116
МК-10Ф-7510-75168425018024500120132
МК-10Ф-10010-100184425018024500120155
МК-11Ф-7511-75179428020024500120155
МК-12Ф-7512-75187428020024500130173
МК-12Ф-10012-100220428020024500130206
МК-16Ф-10016-100280440030036500130345
МК-16Ф-13016-130310440030036500130490
Non-forcible multi-faceted conical straight supports (installation on the ground)
МК-3Г-6031,5601074-----38
МК-4Г-6041,5601164-----49
МК-5Г-6051,5601254-----61
МК-6Г-7561,5751554-----85
МК-7Г-7571,5751654-----100
МК-8Г-7582751734-----126
МК-9Г-7592751824-----144
МК-10Г-75102751914-----162
МК-16Г-1001621003034-----370
Supports more than 12 meters in height produce in two-section type.
MK supports can be made from sheet steel with 3 and 5 mm thickness
METAKO Company reserves the right to change the design and specifications without prior notice.

 

View of the top part of MK support under the corbel

View of the top part of MK support for torchere type lamp

DOCUMENTS

PHOTO


Интересная статья? Поделись ей с другими: